SPECIFICATION
Normal AVR supply power, 2 auxiliary windings
(X1, X2, and Z, Z2)
Shunt supply : 150 - 50/60Hz
Rated overload current: 10A, 10s
Electronic built-in (overload, short circuit, and loss of sensing) protection: if excitation current raises over 10 amps for more then 10 seconds, excitation current will drops automatically to about 1A.
To reset AVR protection, generator must be stopped (or by cutting supply voltage to the AVR)
Protection of power inputs by fuses F1
Voltege sensing: 5VA insulated transformer with input volge taps at:
Terminals 0-110V= 95 to 140V
Terminals 0-220 V = 170 to 260 V
Terminals 0-380 V = 340 to 520 V
Output voltage adjustment by using pot P2
Other sensing voltages by using an adapting other transformers
Current sensing (parallel operation) CT 2.5 VA class 1 secondary current xxx/1 (optiona).
Adjustment of quadrature droop with pot P1
Under-speed (U/F) and LAM protection: for knee frequency adjustable use P4.
Excitation over current adjustment use P5: 4.5 to 10A
For 50/60 Hz (U/F) selection use jumper ST3.
SPECIAL APPLICATIONS
Field de- energizing
Cutting excitation current is accomplished by switching off the supply power to AVR (1 lead on each auxiliary winding)
Contacts capacity : 10A. 250V AC
This is the same connection used to reset internal protection of AVR.
On 17:49 by Unknown in AVR, Generadores, Oaxaca, Piezas para Generadores, Regulador, Regulador Automático de Voltaje, Venta No comments
TECHNICAL DATA
Precisione di regolazione: +/-0.5% a regime, per valori di tensione e carico nominali steady state conditions, for rated Voltage and PF
Deriva Termica: +/- variazione di tensione per variazione T amb 50°C
Voltage Drift: of voltage for 50 -3 Tamb change
Tempo di risposta: 1 ciclo (20ms-16.6ms)
Response Time: 1 cycle (20ms- 16.6ms)
Temperatura di esercizio: -30°C / +70°C
Operating Temperature :
Resistenza di campo eccitatrice: 3.5 (min) + 20 (max)
Exciter field resistance:
Dati di ingresso e uscita:
Input/output data:
- Tensione di alimentazione: 170-277V (50/60Hz)
-Supply voltage:
-Potenza di alimentazione: 1000 VA (max)
-Power supply:
-Potenza dissipata: 30 W (max)
-Power dissipated
-Rilievo di tensione trifase: 170-270 / 380- 415 / 440- 480 V
-Voltage sensing: (three or single phase sensing)
-Tensione di uscita (DC): 80V (max, servizio continuo)
-Output voltage (DC):
-Corrente di uscita (CD) 8A (max, servizio continuo)
-Output current (DC): (max, continuous)
-Corrente di uscita (DC): 15A (max, in forzamento 1 minuto)
-Output current (DC): (max 1 minute forcing)
Suscribirse a:
GLOPMAR
Search
Formulario de contacto
Popular Posts
-
TECHNICAL DATA Precisione di regolazione: +/-0.5% a regime, per valori di tensione e carico nominali steady state conditions, ...
-
Technical specification Sensing Input Voltage 190-264V ac max, 1 phase, 2 wire Frequency 50-60 Hz nominal Power Input (PMG...
-
Technical Data Regulation Accuracy +/- 0.5% rated steady state conditions Voltage Drift: +/- 0.5% voltage change, fo...
-
INTRODUCTION The AVC63-4 voltage regulator is an encapsulated electronic voltage regulator that controls the output of a b...
-
AVR R250 R250 voltage regulator of a sealed electronic devices, by adjusting the excitation current in order to stabilize the output...