El regulador de voltaje SE350 es un regulador de tensión electrónico encapsulado que controla la salida de un generador de corriente alterna sin escobillas mediante la regulación de la corriente en el inductor.
Especificaciones:
- Sensing&power input: 190-240VAC
- Burden: 500VAC
- Out power-continuous: 73VDS at 3.5ADC(255w)
- Out power-forcing(240VAC input power) : 105ADS at 5ADC(525w)
- Regulation : 1.00%
- Remote voltage adjustment range: ±10% with 2000 ohm rheostat
±5 % with 1000 ohm rheostat
- Frequency compensation: adjustable
- Roll off frequency: 54-61 HZ for 60 HZ
45-51 HZ for 50 HZ
- Operation: weight 6.5 oz
- Operation temperature: -40¿ to +60¿
- Storage temperature: -65¿ to +85¿
- Power dissipation: 8 watts maximum
- Size: 3.94"L X 2.66"W X 2.20"H
- Voltage buildup: Internal provisions for automatic voltage
build up from generator residual voltage
as low as 10Vac
- EMI suppression: Internal electromagnetic interference
filter(EMI FILTER)
- Sensing&power input: 190-240VAC
- Burden: 500VAC
- Out power-continuous: 73VDS at 3.5ADC(255w)
- Out power-forcing(240VAC input power) : 105ADS at 5ADC(525w)
- Regulation : 1.00%
- Remote voltage adjustment range: ±10% with 2000 ohm rheostat
±5 % with 1000 ohm rheostat
- Frequency compensation: adjustable
- Roll off frequency: 54-61 HZ for 60 HZ
45-51 HZ for 50 HZ
- Operation: weight 6.5 oz
- Operation temperature: -40¿ to +60¿
- Storage temperature: -65¿ to +85¿
- Power dissipation: 8 watts maximum
- Size: 3.94"L X 2.66"W X 2.20"H
- Voltage buildup: Internal provisions for automatic voltage
build up from generator residual voltage
as low as 10Vac
- EMI suppression: Internal electromagnetic interference
filter(EMI FILTER)
IMPORTANTE:
>Conseguimos cualquier modelo que necesiten contactando por medio de nuestra pagina
Suscribirse a:
GLOPMAR
Search
Formulario de contacto
Popular Posts
-
Technical Data Regulation Accuracy +/- 0.5% rated steady state conditions Voltage Drift: +/- 0.5% voltage change, fo...
-
SPECIFICATION Normal AVR supply power, 2 auxiliary windings (X1, X2, and Z, Z2) Shunt supply : 150 - 50/60Hz Rated...
-
Features > +/- 1% Regulation 220/440 VAC Programmable Input Rugged Compact Desingn Whit Under Frequency Protection Soft S...
-
TECHNICAL DATA Precisione di regolazione: +/-0.5% a regime, per valori di tensione e carico nominali steady state conditions, ...
-
Introduction Sensing Input Voltage 60- 510 VAC single phase 2 wires voltage is DIP switch selectable Frequency 50 / 60 ...


0 comentarios:
Publicar un comentario